TOWN OF CANTON 
PLANNING BOARD MEETING 
WEDNESDAY, JULY 17, 2019 
SALAH MEETING DOOM 
8oi WASHINGTON STREET 
TOWN HAI I JL" 
--00 P.M. 
M01UTES 
Present- Robert Panico, Acting Chairman 
Patricia McDermott, Clerk 
David McCarthy, Member 
Kathy Gibbs McCormack, Membeir 
Also Present: Thomas Houston, Professional Services Corporation 
Laura Smead, Town Planner 
Karen Lawlor, Administrative Assistant 
Acting Chairf man Panico called to order the Planning Board meeting of July 17, 
2010 at 7:00 P-11-1. 
A motion was made by Mr. McCarthy and seconded by Ms. McDermott to open the public 
meeting. Motion Approved 4-0. 
First Item on the Agenda (1) 103 -log ELM STREET (Informal Hearing/Repair 
of Existing Stone Nall & addition of wooden gate) (Jane Eihldorff) 
Acting Chairman Panico explained that Applicant has requested a continuance until the next 
meeting in August. 
Acting Chairman Panico stated that since the next Item is also before the Conservation 
Commission tonight, they are taking the Agenda out of order. 
A motion was made by Mr. McCarthy and seconded by Ms. McDermott to open Item #3 on 
the Agenda. Motion Approved 4-0.

Source page 2

Planning Boai°d Minutes 
July 17, 2019 
Page 2 of 6 
Next Item on the Agenda (3) 19c) BOLIVAR STREET (BOLIVAR POOL) - Site 
Plan Review 
Donald A. Rose, Senior Engineer for CHA, Design/Construction Solutions, introduced 
himself, and explained that the plan is to demolish l00% of the existing pool. They propose 
constructing a five (5) lane pool with water slide; a one —story, 2,240 square foot bathhouse 
building; splash pad area; beach entrance; gravel parking lot; an underground stormwater 
system; an infiltration trench; three (3) paved ADA parking spaces; forty (40) conventional 
parking spaces within a reconfigured gravel parking area; updating of the landscape plan; 
running overhead electric utilities; and new sewer lines which have been approved and 
reviewed by the Engineering Department and PSC. They are also requesting Waivers. 
Mr. Houston stated that Comment #28 - The vehicle used for turning simulation of a Canton 
fire truck. A sketch of the swept vehicle path should be provided. There is one (1) island 
there now, and that will be removed for fire access. The parking lot needs to remain gravel. 
There are a few sign changes; and a smaller infiltration system will decrease the construction 
costs and will provide environmental benefits. If the footprint of the subsurface infiltration 
facility were reduced to the point that it could be confirmed to the portion of the parking 
area above elevation 103, then the bottom of stone of the subsurface infiltration facility can 
be raised and a two (2) foot separation to seasonal high groundwater can be maintained. 
Maintaining a minimum two (2) foot separation allows recharge to be credited. Providing 
recharge establishes compliance with Standard 3 of the Stormwater Management Standards. 
Note that a smaller subsurface infiltration facility is also enabled by separately recharging 
roof water. 
A smaller infiltration system will lower the cost of the project, and due to the recommend - 
dations from the Town and PSC, the Board should send a favorable recommendation on this 
Application. All waivers and permits are acceptable and necessary for this project, especially 
since this is a seasonable pool. 
Ms. McDermott asked why there was no exterior lighting and only two (2) lights on the pool; 
she was also concerned with the life expectancy of the underground pipes. 
Mr. Rose explained that any other lights to be installed will be for security. In regard to the 
pipes: there is 400 feet of pipe and it will have 11/2" of cover. These pipes can erode from 
the water and sediment but PVC pipe will hold up to io years and since they are not 
changing the elevation, the pipe might last a little longer than that. Also, there will be no 
dumpsters and the trash receptacles will be picked up and managed by the Recreation 
Department. 
I)